Gyro 1 fails
Gyro 2 fails
Distribution Unit 1 fails
Distribution Unit 2 fails
Power Supply 1 fails
(connected to Distribution Unit 1)
Power Supply 2 fails
(connected to Distribution Unit 2)
Magnetsonde 1 fails
(connected to Distribution Unit 1)
Magnetsonde 2 fails
(connected to Distribution Unit 2)
6.1
Gyro 1 fails
If the automatic switch--over function G/G is selected (see manual for Operator Unit), the
system (Distribution Unit) switches--over immediately to Gyro 2.
Is this function not selected, a manual switch--over to Gyro 2 has to be carried out.
The message "Switched to GY2" is displayed only, if the automatic switch--over function is
selected.
An alarm is generated acoustical and optical and has to be acknowledged (see manual for
Operator Unit).
This error message "Gyro 1 Failure" can be detached from the Distribution Unit and for-
warded to external alarm devices (detached from the Change over Box too -- if connected).
An automatically switch--over to Magnetic Sonde is only possible if both Gyros fail.
Edition: April 06, 2005
Change Over Box
Error performance
After a RESET of the complete system and Gyro 1 still fails, the
Gyro 2 is designated as Gyro (the numerical indication is no
longer displayed).
After a repair is to pay attention that the repaired Gyro is integra-
ted into the system with the lowest CAN bus address again --
otherwise it will not be identified as Gyro 1.
138- -119
System GG--R
see section 6.1
see section 6.2
see section 6.3
see section 6.4
see section 6.5
see section 6.6
40
System GGM--R
see section 6.1
see section 6.2
see section 6.3
see section 6.4
see section 6.5
see section 6.6
see section 6.7
see section 6.8
3769DOC000002