Below mentioned output signals can be switched--over from the Change Over Box:
-- up to 12 (8) serial outputs (Anschütz course bus or NMEA)
-- 3 x Step (6 steps/degree) 24 / 35 V
-- 1 x rate of turn +/-- 10 V for 30/100/300 degree/minute
-- 1 x RS 232 serial printer interface
-- 2 x Switching status of the Change Over Box
The total amount of relay contacts is shown in the table below:
No. Signal outputs
1
Serial outputs
(Anschütz course bus or
NMEA)
2
Step (6 steps/degree)
3
Rate Of Turn
4
Serial printer interface
5
System Failure DU 1 (2) Status
Edition: April 06, 2005
Change Over Box
138- -119
, max. 10 W
DC
Type of
Number
signal
of
outputs
TX+
up to 12
TX--
GND
S1,
3
S2,
S3,
+35 V,
0 V
RoT Aus
1
RoT GND
TX
1
GND
2
18
Number
of lines
per signal
3
5
2
2
1
3769DOC000002