General Remarks To Establish Cable Connections - Raytheon 138-119 Operator's And Service Manual

Table of Contents

Advertisement

3.1.1

General remarks to establish cable connections

In order to ensure that the system operates correctly, it is essential to follow the procedures
described below for establishing cable connections.
1. Strip off approx. 180 mm of the cable (depending on the distance terminal board or relay
to the cable inlet).
Make sure not to damage the shielding.
2. Strip off the shielding to a remainder of approx. 15 mm.
Figure 5: How to strip a connection cable
3769DOC000002
Change Over Box
138- -119
NOTE!
While closing again the housing after a repair or an
installation, the cover has to be set carefully.
The seal may not be crushed, if necessary push the
sidewall slightly.
approx.
15 mm
approx. 180 mm
13
COMPASS
STD22
Edition: April 06, 2005