Technical Specification; Parameter Settings - ESI ESCTP5-RF Installation Instructions Manual

Hide thumbs Also See for ESCTP5-RF:
Table of Contents

Advertisement

1. Technical specification

Parameter settings

1.1
Set temperature
Program event start/end time
Program operation mode
Number of programs
Manual mode temperature
Holiday mode temperature
Holiday mode days
Operation mode
Hysteresis
Display illumination
6
Auto mode
25°C - 65°C (Default: 55°C)
00:00 - 23:50 (User manual section 6)
5/2 day, 7 day, 24hr (Default: 5/2 day)
2 or 3 (Default: 2)
Manual mode
25°C - 65°C (Default: 55°C)
Holiday mode
25°C - 65°C (Default: 25°C)
1 – 99 (Default: 1)
Delayed start
Auto, manual, OFF (Default: Auto)
2°C - 15°C (Default: 2°C)
On/Off (Default: Off)