3. Main settings

Menu settings

3.1
1. In the home screen, press and hold
shows tInE then release to enter main menu.
2. Use the dial to choose from the options below, press
enter desired setting. Press
tInE: Set time and date.
tEnP: Set desired temperature, use dial to select from
25.0°C -65.0°C. Default is 55°C.
NOP: Select the number of programmes, use dial to
choose 2 or 3. Default is 2.
PrOG: Define programme events. (See user manual
section 6 for details).
HYSt: Set hysteresis, use dial to select between 2.0 – 15.0
°C. Default value 2.0°C.
StEr: Sterelise, legionella prevention function, use dial to
turn ON or OFF. Default is OFF.
LIGH: Display illumination, use dial to turn ON or OFF.
Default is OFF.
rF: RF pairing. (See user manual section 5.8 for details).
WIFI: WiFi pairing. (See user manual section 5.9 for
details).
LOC: Lock screen, use dial and arrows
PIN and lock screen.
RESE: Reset parameters to factory default.
12
until the displays
to return to home screen.
and
to
to set a