Installation Sequence Siting And Levelling The Boiler - Viessmann Vitocrossal 300 Installation Instructions For Contractors

Hide thumbs Also See for Vitocrossal 300:
Table of Contents

Advertisement

Siting and levelling the boiler
Note
Lifting eyes are welded to the top of the boiler for
attaching the lifting gear. Alternatively, use the speci-
fied holes in the boiler floor.
C
B
A
Fig. 5
Lifting gear attachment points:
Lifting the complete appliance
A
Lifting the combustion chamber module
B
Lifting the heat exchanger module
C
Note
If required, base frame
module
can be removed to facilitate handling; see
B
page 10.
When refitting the base support, tighten the four
screws with 70 Nm torque.
8
A
C
B
D
and combustion chamber
D
!
Please note
Risk of crushing and injury.
Secure the combustion chamber module to pre-
vent it from falling.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ct3b

Table of Contents