Installation sequence
Siting the cylinder
!
Please note
Exposure to frost can damage the appliance.
Install the buffer cylinder in a room that is free
from the risk of frost and draughts. Otherwise,
the buffer cylinder must be drained if there is a
risk of frost while it is not in use.
Provide adequate clearance from the wall to allow for
■
operation of the temperature controller (if installed).
■
Placing the heating water buffer cylinder on a plinth
will make the room easier to clean.
■
Use adjustable feet to level the buffer cylinder.
Fitting the lower thermal insulation mat and aligning the cylinder body
1.
A
2.
B
Fig. 1
Bag containing type plate
A
Bag containing 3 adjustable feet
B
3. Insert the adjustable feet into the legs as far as
they will go, then adjust them to level the cylinder
body.
8
!
4.
3.
3x
Please note
The thermal insulation must not come into con-
tact with naked flames.
Exercise caution when welding and brazing.