Hellenbrand AQUA Systems SmartChoice Gen II O3 Installation, Operation And Service Manual page 21

Eradicator with eog ii ozone
Table of Contents

Advertisement

Eradicator Gen II O
Gen II O
Troubleshooting
This table shows the Status light (diagnostic)
parameters and their meaning. The Status light
will tell you the state the EOG II system is in.
It is useful to check normal operation and if there
is service needed.
Status Light
Green light blinking slowly
Green light blinking quickly
Green light solid
Red light solid
Green/Red light alternating
twice per second
Red light flashing
Orange light
21
with Ozone
3
Standby mode; unit is powered, pilot input is OFF.
High voltage startup (up to 3 seconds)
High voltage is ON & stable; CD cell producing ozone
Unstable operation; CD cell may need cleaning
HV is ON, but operating current is low. If persistent, CD cell may
NO or NC contacts are shorted. Remove short condition
1-year timer has expired; clean CD cell, then reset timer by
pressing red "alarm reset" button on PCB once
Copyright ©2021 Aqua Systems, All Rights Reserved • 404 Moravian Valley Road, Waunakee, WI 53597
3
Install & Service Guide
Diagnostic LED
(Status Light)
Condition
need cleaning
Manual Supplement
Alarm
Reset
WARNING
!
ELECTRICAL
HAZARD
+
GND
DISCONNECT POWER
PILOT
BEFORE SERVICING
+
GND
N.O.
N.C.

Advertisement

Table of Contents
loading

Table of Contents