Ozone Wiring Diagram - Hellenbrand AQUA Systems SmartChoice Gen II O3 Installation, Operation And Service Manual

Eradicator with eog ii ozone
Table of Contents

Advertisement

Eradicator Gen II O
Gen II O
Installation
Q 101 . 10
SET
CLOCK
REGEN
NEXT
Drive Motor
Power
wire
wire
9
with Ozone
3
Harness to
EOG II Box
Push the EOG II harness through the strain relief slot that the
4.
power cord went through. Pull through about 10" of the harness.
Then make sure the wire is fully seated in the strain relief slot.
Reinstall the drive bracket (step 2) and the circuit board (step 1)
in the reverse order of removal.
UP
DOWN
Green wire
Connect the power, meter, and drive motor harnesses to the
5.
to Relay 1
DP SW
circuit board as illustrated. Then connect the relay wire
METER
J8 OUTPUT
(green wire) to the relay block in the Relay 1 port and tighten
Meter wire
the set screw until secure.
Copyright ©2021 Aqua Systems, All Rights Reserved • 404 Moravian Valley Road, Waunakee, WI 53597