4.5.6 Hardware Settings
Value Range
Parameter
(default)
Flash Time
1. 100 msec
2. 300 msec
3. 600 msec
4. 900 msec
CPC Signal
1. None
2. 6.5 msec
3. 150 msec
4. 300 msec
5. 450 msec
6. 600 msec
Disconnect
1–8 sec
Time
Dial Mode
1. DTMF
2. Pulse 10 pps
3. Pulse 20 pps
(DTMF)
Note:

4.5.6.3 PBX Interface Parameters

Three types of parameters are used to program the VPS for optimal signaling and
performance with your PBX.
System Administration Top Menu → 1 → 6 → 3
Program – Hardware – PBX Interface Menu
4-78
System Administrator
Specifies the length of time that the hookswitch
must be pressed before the PBX recognizes it as a
flash hook signal. See the manuals of PBX to
determine the correct value.
(100)
[NOTE]
You can select only "1. 100 msec".
Specifies the minimum time required to detect a
break in the CPC (Calling Party Control) signal
from the PBX. The VPS detects that the line has
been disconnected when there is a break of the
CPC signal.
(6.5)
Specifies the amount of time that the line is
(2)
temporarily unavailable to access after a call has
ended.
Specifies dial mode for DTMF or Pulse.
If you specify Pulse, pulse speed (10/20 pps) must
be selected.
[NOTE]
You can not select "3. Pulse 20 pps".
The "Flash" means the register recall in this manual.
1. Dialing Parameters
2. Inband Signaling
3. Digit Translation Table
SELECT ITEM AND PRESS RETURN–KEY
Description/Function
Reference
PBX Type
p.4-79