1
: Check the short circuit wire (1)
and ground wire (2) and replace
wiring harness if necessary.
A faulty ground wire can impair or
prevent operation of the short circuit
wire. For this reason also check the
ground wire for contact and
continuity.
Installing
1
The following steps are shown
without the manifold for greater
clarity.
: Push the wiring harness, short
circuit wire (1) first, into the guide
(arrow).
The cable tie (2) must rest on the
guide and point in the direction of
the cylinder – do not move the cable
tie on the wiring harness.
46
All manuals and user guides at all-guides.com
1
: Fit the wiring harness (1) along
the housing and push it, ground
wire first, completely into the
guide (arrow).
2
2
: Push ground wire connector with
protective tube (2) onto the
contact spring (1).
1
: Push short circuit wire connector
(1) into receptacle on switch shaft
(arrow) as far as stop.
1
1
: Press the wires into the guides
(1) first, then into the guides
(arrows).
The wires must be against the
housing and must not cross each
other.
1
The short circuit wire must be
looped (arrow) so that it can move
with the switch shaft.
: Position the ground wire (1)
against the protective rib (arrow)
– to avoid unintentional
disconnection.