Input Impedance Channel (Ch1; Functional Earth (Shield); Environmental Conditions - Siemens SIPLUS CMS4000 Operating Instructions Manual

Table of Contents

Advertisement

Operating Instructions SIPLUS CMS4000 IFN AI-D
6.2.5
Input Impedance Channel (CH1...CH6)
Z (Ω)
1000000
100000
10000
1000
100
10
1
1,E+00
1,E+01
Picture 16
6.2.6

Functional earth (SHIELD)

Chart 13 Functional earth "SHIELD"
Functional earth (SHIELD)
Connection
Cable recommended
Shield resistance
Shield capacitance
6.2.7

Environmental conditions

Chart 14 Environmental conditions
Environmental conditions
Ambient temperature
Humidity
Atmospheric pressure
Degree of protection
Height of construction over
zero
SIPLUS CMS4000 IFN AI-D
Operating Instructions, 07/2021, A5E32612781A-AB
Input impedance channel (CH1...CH6)
1,E+02
Input impedance channel (CH1...CH6) of an IFN AI-D
Parameter
Screw with detent clip
cross section
Main electronic to SHIELD
Main electronic to SHIELD
Parameter
operating
storage and transport
t = +28...32°C;
1,E+03
1,E+04
min.
typ.
M4
2.5
1000
30
min.
typ.
-40
-40
80
IP67
< 2000 m
Z f(f);
1,E+05
f (Hz)
max.
Unit
2
mm
kΩ
nF
max.
Unit
+65
°C
+85
°C
95
%
110
kPa
32

Advertisement