Checking The Oil Tank Level; Changing The Hydraulic Oil - Jonsered 1250RZ Operator's Manual

Table of Contents

Advertisement

8.5.4. Checking the oil tank level

1.
Place the crane and stabiliser legs in the transport
position.
2.
Place the vehicle on level ground.
3.
Check the oil level in the tank.
4.
Oil level too low:
Top up with hydraulic oil.

8.5.5. Changing the hydraulic oil

WARNING
The oil can be hot and cause injury.
1. Operate the crane for a while to warm the oil. Place the crane in the parked position. Take care
that the temperature of the oil does not exceed the point where you can handle it safely. If this
occurs allow the oil to cool before moving to the next step.
WARNING
• Suitable eye and hand protection must be worn while carrying out this
• Inhalation of oil mist: Contact a doctor.
• Skin contact: Remove polluted clothing, wash with soap and water. In the
• Eye contact: Rinse eyes with plenty of water, see a doctor if irritation
2. Drain the oil tank through the drain plug. Make sure
the system contains as little as possible.
Use a container with sufficient capacity.
3. Change at the same time:
- all filters
4. Refit the drain plug.
NOTE
Ensure the waste oil is disposed of safely and in accordance with local
environmental regulations.
64
Maintenance and Service
operation, and if there is a risk for inhalation of oil mist, a mask as well.
event of high pressure injection of the product, see a doctor without delay.
persists.
Jonsered 1250RZ -1500RZ safety+R CE

Advertisement

Table of Contents
loading

This manual is also suitable for:

1500rz

Table of Contents