Activate stabiliser operation on the user panel by pushing button
Crane with non-tiltable legs
1. Raise the stabiliser leg.
2. Retract the stabiliser extension completely.
Crane with tiltable stabiliser legs
1. Raise the stabiliser leg carefully slightly from the
ground.
2. Unlock the stabiliser leg lock (1). Make sure that it
remains in the released position.
WARNING
Do not stand behind the stabiliser leg. Do not touch the stabiliser leg either.
3. Raise the stabiliser leg slowly until the plate touches the bar on the "inside" of the stabiliser leg.
4. Continue raising the stabiliser leg carefully. It will now move backwards and perform a rotary
movement.
5. Stop the operation as soon as the stabiliser leg is almost vertical, lock the stabiliser leg lock (1).
6. If manual operated stabiliser extension: unlock the stabiliser extension with the handle (2) and
retract the stabiliser extension completely.
7. If manual operated stabiliser extension: lock the stabiliser extension with the handle (2).

7.2. Stabiliser system and boom system

Before switching of the system make sure that the stabiliser extensions and the boom system is in
locked transport position.
Transport warning- Stabiliser extensions
When the stabiliser extensions are locked in
transport position this symbol, one symbol
for each side of the crane, will change to
green and it is safe to move the vehicle.
48
Ending crane operation
Jonsered 1250RZ -1500RZ safety+R CE
.