Download Print this page

Control Panel Problems; Led Display, Leds Not Lit, Buttons, Or Controllers Not Working - Kurzweil CUP2 Service Manual

Advertisement

Control Panel Problems

LED Display, LEDs not lit, Buttons, or Controllers not working

1. Run the Scanner DIAG tests. If the tests pass, the problem is likely the result of a setting
2. Refer to the Interconnect Diagram.
3. Check all related cables. Disconnect and reseat the cables.
4. Check the solder connections at the connectors.
5. Check the ribbon cable from the Control Panel Board to the Interface Board.
6. Check the ribbon cable from the Interface Board, J1, to the Engine Board, J7.
7. Trace the signal path from the connectors on the Engine Board through the Interface Board.
8. Find and replace bad component(s) or order a board replacement.
Keyboard Problems
Dead Keyboard
1. Run the Scanner DIAG tests. If the tests pass, the problem is likely the result of a setting
2. Check the at ribbon cables connecting the Keyboard Bass and Treble Contact Boards to
3. Disconnect and reseat the cables.
4. Check the at ribbon cable connectors at location J1 on the Interface Board and J7 on the
5. Trace the signal path.
6. Find and replace bad component(s) or order a board replacement.
change. Perform a hard reset to the unit or refer to the CUP2 User's Manual.
change. Perform a hard reset to the unit or refer to the CUP2 User's Manual.
the Interface Board, locations J4 and J5 respectively. Be certain that the cables are not loose
or damaged.
Engine Board.
Troubleshooting & Maintenance
Control Panel Problems
5- 5

Hide quick links:

Advertisement

loading