Disassembly/Assembly
Cabinet Electronics
Table 4-2
2. Remove the cable locking clips and disconnect the at ribbon cables in the following order:
3. Disconnect the stranded wire cables in the following order:
Caution: The position of the cable connected to J24 determines the appropriate line voltage.
J24 pins 1 through 4 for 115V or pins 4 through 7 for 230V.
4. Disconnect the shielded wire cables in the following order:
4- 6
Ref.
Name
J1
ScanPort
J3
Pedals
J4
Keyboard Treble
J5
Keyboard Bass
J7
Control Panel
J8
MIDI
J10
USB Control
J11
USB Data
J13
Engine Audio
J14
Slider In to Audio Board
J15
DC Power from Audio Board
J16
Phones from Audio Board
J17
Audio I/O from Audio Board
J23
Power Switch
J24
Transformer Primary
J25
DC Power Out to Engine
Interface Board cables
J5, J4, J1, and J7.
Set the cable locking clips safely aside so that they can be reinstalled when you reconnect
the cables.
J24, J10, J16, J3, J8, and J25.
J23, J11, J17, J13, J14, J15.
Cable Type
at ribbon
Engine Board
stranded wire
Pedal Assembly
at ribbon
Keyboard Assembly
at ribbon
Keyboard Assembly
at ribbon
Control Panel Board
stranded wire
Engine Board
stranded wire
Engine Board
shielded wire
Engine Board
shielded wire
Engine Board
shielded wire
Audio Board
shielded wire
Audio Board
stranded wire
Audio Board
shielded wire
Audio Board
shielded wire
Power Switch
stranded wire
Transformer
stranded wire
Engine Board
Destination