2.4.4 Obtaining and reading data written in flash ROM
emergency1
Note) emergency1 can save up to 32 pieces of data.
When the data exceeds 32 pieces, the data will be erased from the oldest one.
1 emgergency1 data saved
2009/12/11 05:16 90000000
[data0] bit31-bit28
Example: When [data0] is 9*******
[9] in 9******* is <1001> in binary number.
9
data[0]
data[0]
1
0
0
1
bit
31 30
28 27
The allocation table below shows the drop detection setting is ON and the drop distance is 21-40 cm.
bit31
Drop detection setting
bit28-bit30
Drop distance
data[0]
bit0-bit27
Reserved
data[1]
Reserved/Not used
data[2]
Reserved/Not used
data[3]
Reserved/Not used
data[0] data[1]
data[2] data[3]
*
*
*
0: OFF / 1: ON (Indicates the status set on the menu setting screen on the main unit)
0: Drop distance 0-20 / 1: Drop distance 21-40 / 2: Drop distance 41-60 /
Unit:cm
3: Drop distance 61-80 / 4: Drop distance 81-100 / 5: Drop distance 101 or more
Reserved/Not used
*
*
*
*
Hexadecimal number
Binary number
0