„ FUNCTIONS
z MODEL: UTY-DTG  Z1
Item
Indoor unit registration
Installation
Functions setting
Display switching
Display units
Monitor contents (icon
display)
Monitor
Monitor contents (list
display)
Error list
Special state
Control units
Control contents
Detailed control contents
Control
Individual setting reset of
air flow direction
Human sensor
Setting temperature
limitation of room
Language setting
Date and time
Time zone
Panel cleaning and
correction
Group
Background light and
beep sound
Password
Schedule timer
Temperature range
Network
Setting
Low noise operation
Electricity charge
apportionment
Remote language
additional registration
Auto OFF timer
Set temperature auto
return
Display item setting
Failure notification Email
Error history
Status history
Maintenance
Operation history
Version display
Others
External input/output
Main unit
PC / Tablet
Indoor unit registration. Max. 400 units.
z
(Set data can be written to and read from USB flash drive)
Temperature set point limitation, external input, central
z
operation on/off setting.
Icon display, list display
z
z
ALL, group, individual (remote control group)
z
z
Group name, operation, operation mode, set temperature,
z
z
time, errors, timer setting, filter sign
Group name, operation, operation mode, set temperature,
airflow, air direction, special operation, anti-freeze, time,
z
z
errors, timer setting, filter sign
Group name, remote control group name, address, error code
z
z
Display during special operation
z
z
ALL, group, individual (remote control group)
z
z
Operation, operation mode, set temperature, airflow,
z
z
RC Prohibition, filter sign reset
Air direction, energy saving, anti-freeze, test run
z
z
Sets the position of indoor unit's airflow direction louver
z
individually.
Sets the human sensor on the indoor unit.
z
Adjusts the upper and lower limits of temperature for the
z
z
indoor unit.
Design considering multi-language correspondence. *1
z
z
Time display switching, year/month/day display switching,
z
z
system clock setting, summer time
Set the time zone of the area where this unit is used
z
z
Select display area for panel cleaning.
z
User can select black screen on display.
Stages: Max. 3 stages Settable up to 400 groups.
z
z
(Set data can be written to and read from USB flash drive)
Backlighting off time and brightness setting, BEEP sound
z
operation setting
Management level: 3 kinds
z
Max. 30 items settable
z
z
Celsius/Fahrenheit switching, cooling, heating, and AUTO
z
each settable.
function of Email notification for malfunction, or electricity
z
z
charge apportionment option is used via LAN
"Low noise operation" is set to all the outdoor units registered
z
z
by this controller.
Start/stop of ECA, importing/exporting of ECA setting, and
z
z
*2
exporting ECA data.
Additional language can be integrated on remote device by
creating language database.
z
Additional language is displayed on only the remote device
and touch panel controller cannot be added other language.
Function to stop the operation automatically when a preset
z
time lapses after turning on the operation.
Function to restore the temperature to the original set
temperature when a preset time lapses after changing the set
z
temperature.
Sets the items to be displayed on the monitor.
z
Failure notification Email: Sends a notification Email to the
z
preset Email address in the event of failure.
Recording of Max. 10 errors each for touch panel controller
z
z
and each unit (indoor unit, outdoor unit)
Recording of Max. 100 operations each for each indoor unit.
z
z
Writable to USB flash drive.
Recording of Max. 100 operations. Writable to USB flash
z
z
drive.
Version display
z
z
Input: Batch operation/stop, emergency stop, electricity meter
z
Output: Operation monitoring, error
- (05 - 39) -