Changing the SSID and password
NOTICE
Changing the SSID and password
If you want to change network settings such as SSID and password after the Wallbox has
been successfully connected to Siemens Device Management, proceed as follows:
1. Delete the link of the Wallbox with Siemens Device Management via the VersiCharge app
or via VersiCharge Siemens Cloud (https://versicharge.emobility.siemens.cloud/).
2. Repeat the above steps for commissioning.
If a Wi-Fi repeater is used later, we recommend using the same SSID and password that
were used when registering the Wallbox.
Siemens Care Remote Service
Please note: The product includes Care Remote Service during the standard warranty period.
You can find additional information on the SIEMENS Care Service on the Internet
(https://siemens.com/emobility-care).
5.3

Notes on setting up the communication connection

5.3.1

Required open ports

These open ports are required for communication with the Siemens Device Management,
logging server and OCPP server:
• 20
• 21
• 22
• 23
• 123
• 443
• 514
• 9019
• 20000
• Communications port for OCPP. This depends on the server.
VersiCharge AC Wallbox IEC
Operating Instructions, 12/2021, A5E50366109-AA
5.3 Notes on setting up the communication connection
Commissioning
41