Setting Communication; Managing And Using Rfid - Siemens VersiCharge AC Wallbox IEC Operating Instructions Manual

Table of Contents

Advertisement

Modbus map
The Modbus map is available on request from the Download Center (see also
siemens.com/versicharge (https://siemens.com/versicharge)).
5.3.5

Setting communication

Information on the register maps command set is available here.
Supported function codes
Maximum number of RS485 charging units that can be con-
nected to the Parent Modbus unit or Modbus controller
Maximum communication bus length (Modbus RTU)
Note: The standard Ethernet segment lengths apply for
Modbus TCP
Query rate
Standard Modbus TCP server port
The following parameters must be used to establish a Mod-
bus RTU connection
5.4

Managing and using RFID

The Wallbox supports various authentication methods via OCPP.
In addition, it is possible to save the user IDs of authorized RFID cards in a local,
preconfigured list.
You manage the RFID cards via the following channels:
• Modbus controller
• OCPP-based server
• On the device using Admin RFID cards
The management of RFID cards via Admin cards in the local, preconfigured list is described
under Releasing or locking RFID cards.
VersiCharge AC Wallbox IEC
Operating Instructions, 12/2021, A5E50366109-AA
1. 0x03 (read multiple Holding Registers)
2. 0x10 (write multiple Holding Registers)
3. 0x11 (Report Slave ID) – The prerequisite is that a unit is
connected with Modbus
24
304.8 m (1000 ft)
1 s (min. 500 ms)
Port 502
Baud rate = 38400
Parity = even
Data bits = 8
Stop bit = 1
Commissioning
5.4 Managing and using RFID
45