Version Information; A-10-1 Relationship Between Unit Versions - Omron NXEIP202 User Manual

Machine automation controller
Table of Contents

Advertisement

A-10 Version Information
This section describes the relationship between the unit versions of the EtherNet/IP Coupler Units,
CPU Units, and Industrial PCs and the versions of the Support Software.
A-10-1
Relationship between Unit Versions
This section describes the relationship between the unit versions of the EtherNet/IP Coupler Units,
CPU Units, and Industrial PCs and the versions of the Support Software for different system configura-
tions.
If you use any of the combinations of versions/unit versions that are the same or that are later or higher
than the corresponding versions given in the following table, you can use all of the functions that are
supported by that unit version of the EtherNet/IP Coupler Unit. Refer to A-10-2 Functions That Were
Added or Changed for Each Unit Version on page A-70 for the functions that are supported for each
unit version of the EtherNet/IP Coupler Unit.
Refer to version-related information given in the user's manuals of the CPU Unit or Industrial PC for
corresponding versions when using CPU Unit versions, Industrial PC unit versions, and Support Soft-
ware versions that are the same or that are later or higher than the corresponding versions.
Depending on the type and model of the Unit, some Units do not have all of the versions given in the
corresponding versions. If a Unit does not have the specified version, support is provided by the oldest
available version after the specified version. Refer to the user's manuals for the specific Units for the
relation between models and versions.
Connection to the NJ/NX-series CPU Unit or NY-series Industrial PC
The following describes the relationship between the unit versions of the EtherNet/IP Coupler Units, the
unit versions of the NJ/NX-series CPU Units, the unit versions of the NY-series Industrial PCs, and the
versions of the Support Software.
 NX-series CPU Unit or NY-series Industrial PC
EtherNet/IP Coupler Unit
Model
NX-EIC202
*1. The CX-ConfiguratorFDT with version 2.2 or later can be used if it is connected to the peripheral USB port
on the EtherNet/IP Coupler Unit.
 NJ-series CPU Unit
EtherNet/IP Coupler Unit
Model
NX-EIC202
NX-series EtherNet/IP Coupler Unit User's Manual (W536)
Unit version of
Unit ver-
CPU Unit or
sion
Industrial PC
Ver.1.2
Ver.1.14
Ver.1.0
Not possible.
Unit ver-
Unit version
sion
of CPU Unit
Ver.1.2
Ver.1.14
Ver.1.0
Not possible.
Corresponding unit version/version
Network Config-
Sysmac Studio
urator for Ether-
version
Net/IP version
Ver.1.19
Ver.3.21
Not possible.
Not possible.
Corresponding unit version/version
Unit version
Sysmac Stu-
of
dio version
CJ1W-EIP21
Ver.2.1
Ver.1.19
Not possible.
Not possible.
Appendices
CX-Configura-
torFDT version
*1
Ver.2.4
Not possible.
Network
Configura-
CX-Configu-
tor for Eth-
ratorFDT
erNet/IP
version
version
Ver.3.21
*1
Ver.2.4
Not possible.
Not possible.
A - 67
A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx series

Table of Contents