1-5. Setting of Switches on Board

c
c
c
c
c
For the factory-use switch, do not change the factory setting.
RE-153 board
n
To validate the setting, turn on the power of CA-702/P again.
S101-1 (Digital CCZ Disable)
ON:
A VBS signal is output to the VBS line of a CCZ
connector even if the portable VTR compatible with
digital CCZ is connected.
OFF: An SDI signal is output to the VBS line of a CCZ
connector when the portable VTR compatible with
digital CCZ is connected.
Factory setting: OFF
S101-2 (Audio Select 1)
ON:
The audio signal of a camcorder is selected in both 1/2 and 3/4 channels during SDI pool feeding.
OFF: The audio (40P audio) signal from CA is selected in both 1/2 and 3/4 channels during SDI pool
feeding.
Factory setting: OFF
S101-3 (Audio Select 2)
ON:
During SDI pool feeding, the 1/2 channel of a camcorder is selected for a 1/2 channel, and the 1/2
channel of a 40P audio signal is selected for a 3/4 channel.
OFF: Confirms to the Audio Select 1 setting.
Factory setting: OFF
S101-4 (VTR START SW Enable)
OH:
The VTR START switch functions equally with the REC switch of a camcorder in the output
mode.
OFF: The VTR START switch does not completely function in the output mode.
Factory setting: ON
S101-5 (VTR START SW Disable)
ON:
The VTR START switch does not completely function in any modes.
OFF: The VTR START switch functions equally with the REC switch of a camcorder in the input mode.
Factory setting: OFF
CA-702
CA-702P
A
B
C
1
2
3
E1
4
RE-153 BOARD (A SIDE)
1-5. Setting of Switches on Board
F
D
E
CN1
TP106
TP107
TP105
TP108
TP104
S102
TP101 TP102 TP103
E101
S101
1-5(E)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ca-702p

Table of Contents