Table 7-6
Description
Process media temperature (T
● DN15 - DN80
● DN100 - DN150
Process media density (min to max) [kg/m
Process media gauge max pressure [bar (psi)]
Pressure drop
Pressure temperature ratings
Note
Device-specific approvals
Always refer to nameplates on the device for device-specific approvals.
7.4

Certificates and approvals

SITRANS FC410 flowmeter
"Intrinsic safety" type of protection
ATEX
Sira 11ATEX 1341 X
SITRANS FC410
Compact Operating Instructions, 05/2020, A5E39942309-AB
Process media conditions
) (min to max) [°C (F)]
s
Specification
-50 up to +200 [-58 to 392]
-50 up to +205 [-58 to 401]
(lb/ft
]
1 to 5000 (0.06 to 312)
3
3
160 (2321) Hastelloy
100 (1450) st. steel
See Siemens Sizing & Calculation tool
(https://pia-
portal.automation.siemens.com/SIE/
Z3_PIA_PORTAL/
~flNUQVRFPTIwNDg5LjAwMi4wMS4
wMQ==?~okcode=EV_CAL)
See Operating Instructions for FC410
II 1/2 G Ex db ia IIC T* Ga/Gb
II 1/2 G Ex db IIC T* Ga/Gb
1D Ex ia IIIC T*°C Da/Db
2D Ex tb IIIC T*°C Db
Ta = -40°C to +*°C
* Temperature class (dependent on the maximum proc‐
ess temperature and the maximum ambient temperature,
see Special conditions for safe use (Page 15))
Technical data
7.4 Certificates and approvals
43