REMOVE THE OVEN VALVE (SAFETY VALVE)
WARNING
• DISCONNECT power supply cord
from the outlet before servicing.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electric shock.
CAUTION
• Use caution when handling sheet
metal parts while servicing the
range.
- Some parts may have sharp edges, which
could result in injury.
1. Turn off the electrical supply and gas supply
going to the range.
2. Pull the range away from the wall so you can
access the pipe of the unit.
3. To remove the oven valve:
a) Remove the rear back cover and motor cover.
(see step 4~5 on page 3-2)
b) Remove the 4 fittings.
4 connectors
2 screws
4 fittings
COMPONENT ACCESS
& GAS PRESSURE REGULATOR
c) Remove 4 connectors.
d) Remove 2 screws and than lift the oven valve.
4. To remove the Gas pressure regulator.
a) Remove 2 fittings and a gas supplier fitting.
2 fittings
Wool cover back
b) Remove 2 screws from the wool cover back.
3-28
2 screws
Gas supplier
fitting