Characteristics
Degree of protection
IP65
10,000,000 operations min. (under
Mechanical
rated conditions)
Durability
*
Electrical
See the following Electrical Durability.
Operating speed
5 mm/s to 0.5 m/s
Mechanical
120 operations/min
Operating
frequency
Electrical
30 operations/min
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
25 mΩ max. (initial value)
1,000 VAC, 50/60 Hz for 1 min between
terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min between
Dielectric strength
current-carrying metal parts and ground
1,500 VAC, 50/60 Hz for 1 min between
each terminal and non-current-carrying
metal part
Rated frequency
50/60 Hz
Vibration
Malfunction
10 to 55 Hz, 1.5-mm double amplitude
resistance
Destruction
1,000 m/s
Shock
resistance
Malfunction
300 m/s
Ambient operating
−5°C to +65°C (with no icing)
temperature
Ambient operating
35% to 95%RH
humidity
Weight
Approx. 130 to 190 g
Note: 1. The above figures are initial values.
2. The above characteristics may vary depending on the model. For
further details, contact your OMRON sales representative.
* The values are calculated at an operating temperature of +5
an operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
Structure and Nomenclature
Structure
Cover
http://www.ia.omron.com/
2
min.
2
min.
°
°
C to +35
C, and
Resin roller
Lever
Head
Built-in switch
Connector

Engineering Data

Electrical Durability (cos dia. =1)
(Operating temperature: +5°C to +35°C,
Operating humidity: 40% to 70%RH)
Operating frequency:
1,000
30 operations/min
125 VAC (cos dia. = 1)
500
0
1
2
3
4
Switching current (A)
Contact Form
Za
(NO) 4
(NC) 1
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
HL-5000
5
6
3 (NO)
2 (NC)
2