9.3 Resetting a Device's Wireless Settings

If you encounter an issue at any point during the wireless network setup process, you may reset the device by following
the directions below.
A. begIn reSet
Press and hold the button on the device for 8-9 seconds until you hear 3
beeps. Release button. You will hear the words "Resetting wireless settings."
b. ConClUde reSet
Light ring will flash green once and then it will pulse red. You will hear the
words, "Ready to connect, follow quick start instructions."
Device has been reset.
See Section 9.1 to begin set-up of a new wireless alarm network,
or Section 9.2 for adding this device to an existing alarm network.
note:
If no further steps are taken within 15 minutes of resetting the unit's wireless settings, a voice prompt "No
devices found, not connected" will be heard once, and the wireless function will turn off. The unit will then perform as
a standard hardwired alarm. See Section 9.2 for adding this device to an existing alarm network.

10. Wiring Instructions

Wiring requirements
This alarm should be installed on a UL Listed or recognized junction box. All connections should be made by a
qualified electrician and all wiring used shall be in accordance with articles 210 and 300.3(B) of the U.S. National
Electrical Code ANSI/NFPA 70, NFPA 72 and/or any other codes having jurisdiction in your area. The multiple station