Chapter 6. Configuring DTE Options

Table 6-6. Short and Long Delays at Different Operating Speeds

Anti-Stream

The A
-S
NTI
TREAM
6-8 on page 6-11 shows the menu path used to access the A
tions menu. The anti-stream timeout is the maximum time the DSU III
ARdc transmits data to the network from the DTE. This feature prevents
one DTE device on a multi-drop network from continuously tying up the
transmit circuit back to the master DSU.
The anti-stream timer is reset to zero when RS changes to the active state
and is updated every second while RS is active. When the anti-stream tim-
eout expires, the DSU III ARdc stops transmitting DTE data into the net-
work but continues to accept data from it. This condition exists until the
DTE deactivates the RS input.
6-10
Rate
64K
56K
38.4K
19.2K
9.6K
4.8K
2.4K
option is used to select the anti-stream timeout. Figure
DSU III ARdc User Manual
Short
Long
Option
Option
1.1ms
16.1ms
1.1ms
16.1ms
1.5ms
16.5ms
1.5ms
16.5ms
1.5ms
16.5ms
1.9ms
16.9ms
3.8ms
18.8ms
Tolerance
±.4ms
±.4ms
±.4ms
±.4ms
±.4ms
±.7ms
±1.3ms
-S
op-
NTI