Chapter 2. Installation
The chassis should be connected to earth ground.
The following UL requirements must be met during installation:
1.
The unit must be connected to a reliably grounded -24 or -48 VDC
source which is electrically isolated from the AC source.
2.
The branch circuit overcurrent protection should be a fuse or circuit
breaker rated 48 V, 15 A.
3.
The unit should be installed in accordance with the requirements of
NEC NFPA 70.
4.
A readily-accessible disconnect device, that is suitably approved and
rated, should be incorporated in the fixed wiring.

NETWORK INTERFACE CONNECTION

The DSU III ARdc's eight-position modular jack (labeled TELCO) connects
to the network when the unit is configured for either dedicated or
switched operation. See Table 2-1 for the connector pin assignments.
Pin
1
2
3-6
7
8
2-2

Table 2-1. Pin Assignments for Telco Connector

Name
R1
Transmit Data from DSU to Network-Ring 1
T1
Transmit Data from DSU to Network-Tip 1
-
Not Used
T
Receive Data from Network to DSU-Tip
R
Receive Data from Network to DSU-Ring