Fagor FTG6-05L General Instruction For Installation Use And Maintenance page 30

Gas fry-top
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 26
Burner conversion
Injector replacement.
Dismantle the burners' "A" injectors (Fig. 2) and replace them with suitable ones depending on the gas to
be used (Table 3)
Burner air adjustment.
Position the air regulator "B" (Fig. 2) to the "H" measurement (Table 3) depending on the gas to be used.
Pilot conversion and adjustment
To convert to NATURAL GAS, please proceed as follows: Loosen screw "A" (Fig. 3, DETAIL A).
The 0.25 mm injector "B" is underneath screw "A" which must be loosened and replaced by the 0.40 mm
injector supplied with the nozzles.
Turn the air regulator "C" until the flame steadies (Fig. 3).
To convert to TOWN GAS, the pilot flame adjustment is carried out turning the adjusting screw "B" until the
flame is stable. IMPORTANT NOTE: Any adjustment or replacement should be carried out by an AUTHORISED
TECHNICIAN
Valve tap minimum flow rate adjustment.
To adjust the minimum flow of the gas tap, the burner must have been on for at least 15 minutes and then
the F adjusting screw pressed down completely in the case of G.L.P. or by adjusting this screw,
anticlockwise until a stable flame is achieved, in the minimum for Natural Gas and Town Gas (Fig. 4).
After adapting the equipment to another type of gas or to another pressure, other than that for which it had
been previously set, the old instructions should be replaced with the instructions for the new settings, to
enable unambiguous identification of the state of the equipment after modification.
When the appliance has been installed, clean the surface of the grille. Use water and detergent, do not
use abrasive products. When cleaning, cover the grease exit hole.
Do not use water hoses to clean the appliance.
Burner ignition
Valve tap
a)
Open the gas mains tap.
b)
Lightly press the gas mains tap control to unlock it and turn it anticlockwise to position 2 (PILOT)
c)
Keep the control pressed while igniting the pilot and keep it pressed for 20 seconds until the flame
becomes stable, in order for it to stay on when the control is released.
d)
The appliance has a hole on the front panel for manually igniting the pilot.
e)
To ignite the burner, press the control and turn it anticlockwise to position 3 (MAXIMUM), position 4
(MINIMUM). When the required position is reached, stop pressing the control. The burner will have
been ignited by the pilot.
f)
If we position the control at 1 (OFF) the appliance will stop working.
2.-USE
Turning the appliance on