Wiring Schematics cont.
Aurora Base with PSC cont.
Communicating Thermostat
To Fossil Fuel
Furnace W input
Dual Fuel Wiring Diagram
Using Field Installed Relay
Note 8: Field installed SPST dual fuel relay
(Required for dual fuel installation)
EH1
ABC
24VDC
Board
C
Aurora LED Flash Codes
Slow Flash
1 second on and 1 second off
Fast Flash
100 milliseconds on and 100 milliseconds off
Flash Code
100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating
Configuration LED (LED2, Yellow)
Random Start Delay (Alternating Colors)
Status LED (LED1, Green)
Fast Flash
No Software Overide
Configuration LED (LED2, Yellow)
Fast Flash
DIP Switch Overide
Fault LED (LED3, Red)
Fast Flash
Fault LED (LED1, Red)
Status LED (LED3, Green)
Normal Mode
OFF
Normal Mode
Input Fault Lockout
Flash Code 1
Control is Non-Functional
High Pressure Lockout
Flash Code 2
Test Mode
Low Pressure Lockout
Flash Code 3
Lockout Active
Future Use
Flash Code 4
Dehumidification Mode
Freeze Detection – FP1
Flash Code 5
Future Use
Reserved
Flash Code 6
Future Use
Condensate Overflow Lockout
Flash Code 7
Load Shed
Over/Under Voltage Shutdown
Flash Code 8
ESD
Future Use
Flash Code 9
Future Use
Future Use
Flash Code 10
FP1 Sensor Error
Flash Code 11
Aurora Timing Events
Event
Normal Mode
Random Start Delay
5 to 80 seconds
Compressor On Delay
5 seconds
Compressor Minimum On Time
2 minutes
Compressor Short Cycle Delay
4 minutes
Blower Off Delay
30 seconds
Fault Recognition Delay – High Pressure
Less than 1 second
Start-Up Bypass – Low Pressure
2 minutes
Fault Recognition Delay – Low Pressure
30 seconds
Start-Up Bypass – Low Water Coil Limit
2 minutes
Fault Recognition Delay – Low Water Coil Limit
30 seconds
Fault Recognition Delay – Condensate Overflow
30 seconds
Thermostat Call Recognition Time
2 seconds
Comfort Alert Recognition Time
90 seconds
Auxiliary Heat Staging Delay
5 minutes
Emergency Heat Staging Delay
2 minutes
Water Valve Slow Open Delay
90 seconds
Notes
1 - Switch blue and red wires for 208V operation.
2 - The blk/wh and gray/wh wires are removed when Aux Heat is installed
3 - Use manufacturer's part number 19P592-01 (jumper bar assembly) when single source power is
required.
4 - When connected the Auxiliary Heat powers blower and controls. Wires are secured at blower.
5 – Low voltage wiring CLASS 2.
6 - Refer to FAN SPEED table for factory settings.
7 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower.
8 - Field installed SPST relay required for dual fuel installation.
9 – Ground wire only on units with aluminum air coils.
FACTORY SET FAN SPEED
UNIT
STANDARD PSC
12
H
18
M
22
M
30
M
36
M
42
M
48
M
60
M
70
H
UNIT
HIGH STATIC PSC
22
M
30
M
36
M
42
M
48
M
ABC SW2 Accessory Relay
DESCRIPTION
SW2-4
Cycle with Blower
ON
Cycle with Compressor
OFF
Water Valve Slow Opening
ON
Cycle with Comm. T-stat Hum Cmd
OFF
The manufacturer works continually to improve its products. As a result, the design and specifi cations of each product at the time of order may be changed without notice. Purchaser's approval of this data set signifi es that the equipment is acceptable under the provisions
of the job specifi cation. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely the manufacturer's opinion or commendation of its products. York and Affi nity are registered
trademarks of Johnson Controls, Inc., and are used with permission.
SD2500AK6
06/21
P.O.:
Unit Tag:
R from Fossil
Fuel Furnace
NOTE 4
To PB2
OFF
Slow Flash
ON
OFF
Slow Flash
Fast Flash
Green
Flash Code 2
Flash Code 3
Flash Code 4
Flash Code 5
1
2
3
4
Flash Code 6
Flash Code 7
Connects to variable
speed ECM motor only
Test Mode
1 second
< 1 second
5 seconds
15 seconds
2 seconds
CSA installed units only
Less than 1 second
Local codes may require a single
30 seconds
source of power supply
30 seconds
Single Disconnect Power
30 seconds
30 seconds
208-230/60/1
30 seconds
Breaker box
L1
L2
2 seconds
furnished by
90 seconds
installer
20 seconds
7.5 seconds
90 seconds
Circuit Breakers
L1
L2
L1
Aux Elect Power
Unit Power
208-230/60/1
208-230/60/1
LED1
FP1 – 15
HP
ECM PWM
P4
R
FP2 – 15
HP
P13
LP
Fault
LP
ACC – Dip 4
FP2
ACC – Dip 5
FP2
LED3
CC – Dual/Single
FP1
SW1 Test
G
FP1
L – Pulse/Continuous
REV
Status
Reheat/Normal
REV
RV – K1
CC2
AURORA BASE
CC – K2
CONTROL™
G
P5
CC Hi – K3
LO
HI
CCG
CC
Fan – K4
FG
F
P11
R
Alarm – K5
SW2-5
ON
JW2 - Alarm
OFF
F
Acc – K6
OFF
CC
ON
P9
Factory Fan Connection
G
Y1
Field Connections
Field Connections
P2
P1
With optional EA Series 10kW Auxiliary Electric Heat shown
Place auxiliary heat schematic from kit here
P9
1
2
Green
3
Brown
5
Brown
Orange
4
Orange
Blue
Violet
Black
Gray
G
5
P11
G
G
G
EA Series
PCB
P2
C
1
2
3
4
C
1
P3 from unit's control box
connects to P2
L2
On
Off
LED2
1
F/30
F
o
o
EH1
2
Y
F/30
F
o
o
RV – B/O
3
Config
P3
EH2
4
C
5
EH1
C
6
CO
7
N/A
8
SW2
(+)
P6
(-)
R
C
L1
(+)
LED5
P7
(-)
G
Com1
R
C
P8
LED4
CC -
CO -
G
Com2
K5 -
K6 -
CR3 -
CR4 -
CS -
F1 and F2 -
HE -
HP -
ER1 to ER4 -
LP -
R
R
59
Affinity & Affinity Advanced Series
1 - Use copper or aluminum conductors.
208-230/60/1
2 – When Auxiliary Heat is installed the BLK/WHT
wire from CC-L1 to PB2-2 and the GRY/WHT wire
from CC-L2 to PB2-1 must be removed (located in
the heat pump control box).
3 – Jumpers wires are Factory Installed, and are
G
L1
L2
Required for auxiliary heat operation.
4 - When installed the Auxiliary Heat powers blower and controls.
5 – Low voltage wiring CLASS 2.
Black
Gray
TB
ER
1
HE1
Gray
Gray
N
O
TS1
ER
2
HE2
Black
Black
N
O
TS2
Gray
ER
3
Gray
N
O
Black
ER
4
Black
N
O
P1
2
3
4
NOTE 3
Legend
Factory Low voltage wiring
Thermistor
T
Factory Line voltage wiring
Field low voltage wiring
Light emitting diode - Green
G
Field line voltage wiring
Optional block
Relay coil
DC Voltage PCB traces
Junction
Capacitor w/ bleed resistor
Quick connect terminal
Switch - Condensate overflow
Wire nut
Switch - High pressure
Field wire lug
Switch - Low pressure
Ground
Relay Contacts-
2
3
1
Polarized connector
N.O., N.C.
P
Fuse
Current Transducer (CT)
Breaker
PB1, PB2 -
Power blocks
Compressor Contactor
PS -
Power strip
Condensate overflow sensor
DHW pump relay
RV -
Reversing Valve coil
Loop pump relay
SW1 -
DIP package 5 position AXB
PSC Fan Speed Relay
SW1 -
TEST MODE ABC Board
PSC Fan Power Relay
SW2 -
DIP package 8 position ABC Board
Compressor Solenoid
TS -
Thermal limit switch
Fuses
HWL -
Hot water limit sensor
Heater element
SC -
Start Contactor
High pressure switch
SR -
Start Relay
Aux heat stage relays
WCL -
Water Coil Limit Sensor
Low pressure switch
1 - 6 Tons 60Hz
Page _____ of _____