York YAFS012-018 Manual page 55

Table of Contents

Advertisement

Contractor:
Engineer:
Project Name:
Wiring Schematics cont.
Aurora Advanced with 5-Speed ECM cont.
The manufacturer works continually to improve its products. As a result, the design and specifi cations of each product at the time of order may be changed without notice. Purchaser's approval of this data set signifi es that the equipment is acceptable under the provisions
of the job specifi cation. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely the manufacturer's opinion or commendation of its products. York and Affi nity are registered
trademarks of Johnson Controls, Inc., and are used with permission.
SD2500AK6
06/21
P.O.:
Unit Tag:
NOTE 3
P11
Brown
5
4
Orange
Green
3
2
Brown
1
Green
5 Speed ECM
Blower Motor
Orange
5
4
3
2
1
C
Breaker box
furnished by
installer
Aux Elect Power
Notes
1 - Switch blue and red wires for 208V operation.
2 - The blk/wh and gray/wh wires are removed when Aux Heat is installed
3 – When Auxiliary Heat is field installed the harness will be connected to the auxiliary
heat unit. The auxiliary heat unit will then power the blower. Refer to EAS/EAM/EAL
Auxiliary Heat kit installation instructions. Wires are secured at blower
4 – Low voltage wiring CLASS 2.
5 - Y2 input wire Tan not connected on Single Speed units. Wire is secured at blower.
6 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower.
7 – Brown blower power wire routed through Current Transducer two times.
8 – Field Connected: Refer to Installation Manual and Auxiliary Heat Instructions for
Current Transducer installation.
9 – Variable speed pump low voltage harness provided with Variable Speed Flow Center.
10 – Variable speed pump power wires to connect the pump to L1 and L2 on the AXB board
are provided with Variable Speed Flow Center.
11 - Field installed SPST relay required for dual fuel installation.
12 - Refer to units 5 SPEED ECM MOTOR LOW VOLTAGE CONNECTION table for
factory settings.
13 – Ground wire only on units with aluminum air coils.
7/27/2015
With optional EA Series 10kW Auxiliary Electric Heat shown
Place auxiliary heat schematic from kit here
P9
1
NOTE 4
2
Green
3
Brown
5
To PB2
Orange
4
Blue
Violet
Green
1
2
3
4
5
P11
Connects to variable
speed ECM motor only
CSA installed units only
Local codes may require a single
source of power supply
Single Disconnect Power
208-230/60/1
L1
L2
C
1
2
P3 from unit's control box
connects to P2
Circuit Breakers
L1
L2
L1
L2
Unit Power
208-230/60/1
208-230/60/1
L1
CC -
CO -
K5 -
K6 -
CR3 -
CR4 -
CS -
F1 and F2 -
HE -
HP -
ER1 to ER4 -
LP -
55
Affinity & Affinity Advanced Series
1 - Use copper or aluminum conductors.
208-230/60/1
2 – When Auxiliary Heat is installed the BLK/WHT
wire from CC-L1 to PB2-2 and the GRY/WHT wire
from CC-L2 to PB2-1 must be removed (located in
the heat pump control box).
3 – Jumpers wires are Factory Installed, and are
G
L1
L2
Required for auxiliary heat operation.
4 - When installed the Auxiliary Heat powers blower and controls.
5 – Low voltage wiring CLASS 2.
Brown
Black
Orange
Gray
TB
ER
Black
1
Gray
HE1
Gray
Gray
N
G
O
TS1
ER
2
HE2
Black
Black
N
G
O
TS2
Gray
ER
3
N
Gray
O
G
Black
ER
4
Black
N
O
G
EA Series
PCB
P2
P1
3
4
C
1
2
3
4
NOTE 3
Legend
Factory Low voltage wiring
Thermistor
T
Factory Line voltage wiring
Field low voltage wiring
G
Light emitting diode - Green
Field line voltage wiring
Optional block
Relay coil
DC Voltage PCB traces
Junction
Capacitor w/ bleed resistor
Quick connect terminal
Switch - Condensate overflow
Wire nut
Switch - High pressure
Field wire lug
Switch - Low pressure
Ground
Relay Contacts-
2
3
1
Polarized connector
N.O., N.C.
P
Fuse
Current Transducer (CT)
Breaker
PB1, PB2 -
Power blocks
Compressor Contactor
PS -
Power strip
Condensate overflow sensor
RV -
Reversing Valve coil
DHW pump relay
Loop pump relay
SW1 -
DIP package 5 position AXB
PSC Fan Speed Relay
SW1 -
TEST MODE ABC Board
PSC Fan Power Relay
SW2 -
DIP package 8 position ABC Board
Compressor Solenoid
TS -
Thermal limit switch
Fuses
HWL -
Hot water limit sensor
Heater element
SC -
Start Contactor
High pressure switch
Start Relay
SR -
Aux heat stage relays
WCL -
Water Coil Limit Sensor
Low pressure switch
1 - 6 Tons 60Hz
Page _____ of _____