Wiring Schematics cont.
Aurora Advanced with ECM and IntelliStart cont.
NOTE 3
Brown
Orange
Green
1
2
3
4
5
P11
ECM
Blower
Motor
12 15 10
16 1
3 3
P12
Violet(42)
Blue(24)
Yellow(25)
Green/Yellow(28)
NOTE 9
To P2 on
Electric Heat
Board
The manufacturer works continually to improve its products. As a result, the design and specifi cations of each product at the time of order may be changed without notice. Purchaser's approval of this data set signifi es that the equipment is acceptable under the provisions
of the job specifi cation. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely the manufacturer's opinion or commendation of its products. York and Affi nity are registered
trademarks of Johnson Controls, Inc., and are used with permission.
SD2500AK6
06/21
P.O.:
Unit Tag:
With optional EA Series 20kW Auxiliary Electric Heat shown
NOTE 4
Green
Brown
To PB2
Orange
Blue
Violet
Green
1
2
3
4
5
P11
Connects to variable
speed ECM motor only
CSA installed units only
Local codes may require a single
source of power supply
Single Disconnect Power
208-230/60/1
Breaker box
L1
L2
furnished by
installer
Circuit Breakers
L1
L2
L1
L2
Aux Elect Power
Unit Power
208-230/60/1
208-230/60/1
Notes
1 - Switch blue and red wires for 208V operation.
2 - The blk/wh and gray/wh wires are removed when Aux Heat is installed
3 – When Auxiliary Heat is field installed the harness will then be connected to
the auxiliary heat unit. The auxiliary heat unit will then power the blower. Refer to
EAS/EAM/EAL Auxiliary Heat kit installation instructions.
4 – Low voltage wiring CLASS 2.
5 – Brown blower power wire routed through Current Transducer two times.
6 – Field Connected: Refer to Installation Manual and Auxiliary Heat Instructions for
Current Transducer installation.
7 – Variable speed pump low voltage harness provided with Variable Speed Flow Center.
8 – Variable speed pump power wires to connect the pump to L1 and L2 on the AXB board
are provided with Variable Speed Flow Center.
9 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower.
10 – Ground wire only on units with aluminum air coils.
Place auxiliary heat schematic from kit here
208-230/60/1
208-230/60/1
Circuit 2
Circuit 1
NOTE 2
G
L2
L1
L2
L1
G
P9
1
2
3
Brown
5
Orange
4
Yellow
Gray
G
Black
G
Yellow
G
Pink
G
P2
C
1
2
3
4
P3 from unit's control box
connects to P2
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Junction
Quick connect terminal
Wire nut
L1
Field wire lug
Ground
Relay Contacts-
N.O., N.C.
Fuse
Breaker
CC -
Compressor Contactor
CO -
Condensate overflow sensor
K5 -
DHW pump relay
K6 -
Loop pump relay
PSC Fan Speed Relay
CR3 -
PSC Fan Power Relay
CR4 -
CS -
Compressor Solenoid
F1 and F2 -
Fuses
HE -
Heater element
HP -
High pressure switch
ER1 to ER4 -
Aux heat stage relays
LP -
Low pressure switch
51
Affinity & Affinity Advanced Series
1 - 6 Tons 60Hz
1 - Use copper or aluminum conductors.
2 - Use manufacturer's part number 19P592-01 (jumper
bar assembly) when single source power is required.
3 – When Auxiliary Heat is installed the BLK/WHT
wire from CC-L1 to PB2-2 and the GRY/WHT wire
from CC-L2 to PB2-1 must be removed (located in
the heat pump control box).
4 - When installed, the Auxiliary Heat powers blower and controls.
5 – Low voltage wiring CLASS 2.
6 – Jumpers wires are Factory Installed, and are
required for auxiliary heat operation.
Black
Gray
EHC
Pink
Gray
ER1
Gray
NO
Blue
HE1
TS1
EHC
Black
ER2
Black
NO
HE2
TS2
Yellow
Blue
ER3
Yellow
HE3
NO
TS3
ER4
Pink
Pink
NO
HE4
TS4
EA Series PCB
P1
C
1
2
3
4
NOTE 6
Legend
Thermistor
T
G
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
2
3
1
Polarized connector
P
Current Transducer (CT)
PB1, PB2 -
Power blocks
PS -
Power strip
RV -
Reversing Valve coil
SW1 -
DIP package 5 position AXB
SW1 -
TEST MODE ABC Board
SW2 -
DIP package 8 position ABC Board
TS -
Thermal limit switch
HWL -
Hot water limit sensor
SC -
Start Contactor
SR -
Start Relay
WCL -
Water Coil Limit Sensor
Page _____ of _____