Advertisement

Functions
Sensor functions/
status indications
Activate / deactivate
call diversion
Switching without
feedback
Switching with feedback
Button not assigned
Each function key of the comfort keypad can be programmed so that the belonging
LED indicates the contact state of a detector (an attention tone sounds).
Additionally, an allocated function can be triggered by pressing the button next to the
LED.
The LED expires if the indicated status ends, an attention tone sounds.
Each function key of the comfort keypad can be programmed so that incoming door
calls are diverted to any indoor station.
Activate: press the function key, the LED is on.
Deactivate: press the function key again, the LED expires.
Pressing a function key of the comfort keypad sends a control function. The LED next
to the function key is not activated.
Press the function key.
A control function is sent; this one can be allocated to different functions within the
system (button 1: control function 11 .... button 10: control function 20).
Pressing a function key of the comfort keypad sends alternaltive two control functions
(On/Off). The LED next to the function key is activated resp. deactivated.
Press the function key, the LED expires.
A control function is send (button 1: control function 11 to button 10: control function
20).
Press the function key again, the LED expires. Another control function is send
(button 1: control function 41 .... button 10: control function 50).
When pressing the function key no signal is send (delivery state).
Operating the function keys 1 - 10