Parts
EQc and EQ200T / EQ400T Models
1.
Apply thread sealant to all non-swivel pipe threads.
Apply anti-seize to threads.
2
Torque to 60 +/- 5 ft-lb (81.3 +/- 6.7 N•m) with pot
3
pressurized.
Torque to 15 +/- 2 ft-lb (20.3 +/- 2.7 N•m).
4
42
Apply anti-seize to enclosure mounting studs.
5
Torque to 25–30 ft-lb (34-40.6 N•m).
6
The handway gasket must be assembled centered and flat
7
on the handway cover.
3A7467D