Models - Graco HFR Setup And Operation Manual

Hydraulic, plural-component, fixed-ratio proportioner for pouring and dispensing sealants and adhesives and polyurethane foam
Hide thumbs Also See for HFR:
Table of Contents

Advertisement

Models

Models
See Product Configurator on page 5 for detailed product configuration information.
Full Load
Peak
Amps Per
System
Phase*
55 A
HFR,
29 A
Non-Heated
55 A 
116 A
HFR,
73 A
Heated
63 A 
*
Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and
mix chamber sizes may be less.
210 ft (64 m) maximum heated hose length, including whip hose.
approved.
‡ The maximum fluid working pressure for the base machine without hoses is 3000 psi (20.7 MPa, 207 bar). If
hoses rated at less than 3000 psi are installed, the system maximum fluid working pressure becomes the rating of
the hoses. If 2000 psi hoses were purchased and installed by Graco, the working pressure for the machine is
already setup for the lower 2000 psi (13.8 MPa, 138 bar) working pressure by Graco. If the machine was pur
chased without hoses and aftermarket hoses rated at or above 3000 psi are to be installed, see instruction man
ual 313998 for the procedure to setup the machine for higher rated hoses. The change in working pressure is
made by changing a rotary switch setting in the Motor Control Module. The minimum pressure rating for hoses is
2000 psi. Do not install hoses with a pressure rating lower than 2000 psi.
 See 400 V Power Requirements.
400 V Power Requirements
400 V systems are intended for International voltage
requirements. Not for voltage requirements in North
America.
If a 400 volt configuration is operated in North Amer
ica, a special transformer rated for 400 V ("Y" con
figuration (4 wire)) may be required.
4
Voltage
(phase)
Power Description
200-240VAC, 1 phase, 50/60Hz,
230V (1)
2 wire and PE
200-240VAC, 3 phase
230V (3)
wire and PE
380-415VAC, 3 phase Y, 50/60Hz,
400V (3)
2 wire and PE
200-240VAC, 3 phase
230V (1)
wire and PE
200-240VAC, 3 phase
230V (3)
wire and PE
380-415VAC, 3 phase Y, 50/60Hz,
400V (3)
2 wire and PE
System Watts †
12, 650
Δ
, 50/60Hz, 3
11,340
12,650
Δ
, 50/60Hz, 3
26,680
Δ
, 50/60Hz, 3
28,600
28,600
North America mostly employs a 3 wire or Delta
configuration. The two configurations are not inter
changeable.
Maximum
Fluid Working
Pressure ‡
psi (MPa, bar)
3000
(20.7, 207)
3000
(20.7, 207)
313997ZAA