You can install one or two I/O modules in slot 1 and 2 of the FortiGate-5050 ATCA
chassis. You can also install up to three worker modules in slots 3 to 5 if two I/O
modules are being used, or four worker modules in slots 2 to 5 if one I/O module
is used. The FortiGate-5050 is a 5U chassis that contains two redundant DC
power connections that connect to -48 VDC Data Center DC power. The
FortiGate-5050 chassis also includes a hot swappable cooling fan tray. For details
about the FortiGate-5050 chassis, see the
Figure 5: FortiGate-5005-DIST components installed in a FortiGate-5050 chassis
ACT
USB
USB
LINK
1
5
ACT
LINK
CONSOLE
OOS
ACC
STATUS
ACT
USB
USB
LINK
1
4
ACT
LINK
CONSOLE
OOS
ACC
STATUS
ACT
USB
USB
LINK
1
3
ACT
LINK
CONSOLE
OOS
ACC
STATUS
ACT
USB
USB
LINK
1
2
ACT
LINK
CONSOLE
OOS
ACC
STATUS
DATA
X 1
X 2
1
5
9
13
1
2
6
10
14
X 1
3
7
11
D
15
X 2
4
8
12
D
16
10/100/1000 MBPS ETHERNET ACTIVITY
STATUS
PAYLOAD OPERATION
5000SM
5050SAP
SMC
10/100
link/Act
SERIAL
2
10/100
1
link/Act
The FortiGate-5005-DIST worker web-based manager and CLI use an internal
naming convention to name FortiGate-5005-DIST interfaces. The interface names
indicate the I/O module containing the interface and also include the I/O module
front panel interface name. The naming convention is:
port<I/O_module_number>_<I/O_module_interface_name>
where:
<I/O_module_number> is 1 for the interfaces of the primary I/O module
installed in chassis slot 1 and 2 for the interfaces of the secondary I/O module
installed in chassis slot 2. The interfaces for the secondary I/O module only
appear in the web-based manager and CLI when a secondary I/O module is
installed.
<I/O_module_interface_name> is the name of the interface as shown on the
FortiController-5208 front panel.
Table 1 on page 10
shows the relationship between the names of the primary and
secondary module front panel interfaces and the interface names that appear on
the FortiGate-5005-DIST worker web-based manager and CLI.
FortiGate-5050 Chassis
7
8
2
3
4
5
6
IPM
7
8
2
3
4
5
6
IPM
7
8
2
3
4
5
6
IPM
7
8
2
3
4
5
6
IPM
CONTROL
1
5
9
13
1
MANAGEMENT
COM 1
COM 2
2
6
10
14
2
1/2
3/4
D15/D16
C15/C16
3
7
11
C
15
3
4
8
12
C
16
4
IPM
5000SM
10/100
SERIAL
link/Act
2
10/100
link/Act
FortiGate-5005-DIST interface names
Guide.
POWER
SMC
1
9

Advertisement

Table of Contents
loading

Table of Contents