Powering off the FortiGate-5005-DIST system

Powering off the FortiGate-5005-DIST system
30
To avoid potential hardware problems or data loss, always shut down the modules
before powering down the chassis.
Note: Executing a shutdown command will shut down the module's operating system. The
module itself will still receive power from the chassis and indicator lights on the module may
remain lit after a successful shut down operation.
Using the CLI to shut down the FortiGate-5005-DIST system
1
Connect to the primary I/O module and shut down the worker modules.
execute worker shutdown
2
If present, shut down the secondary I/O module.
execute secondary-io
execute shutdown
exit
3
Shut down the primary I/O module.
execute shutdown
You can now safely turn off power to the chassis.