Installing FortiGate-5005-DIST firmware

Viewing the currently installed firmware versions

Upgrading I/O module firmware

32
You also install FortiGate-5005FA2 DIST firmware on the primary I/O module. The
primary I/O module synchronizes this firmware to all FortiGate-5005FA2 modules.
This happens even if the FortiGate-5005FA2 modules are running newer firmware
versions. Also, if different FortiGate-5005FA2 modules are running different
firmware versions, the system synchronizes them all to run the worker firmware
version installed on the primary I/O module.
FortiController-5208 modules are shipped with FortiController-5208 and
FortiGate-5005FA2 firmware installed. So, as you are installing your
FortiGate-5005-DIST hardware, the system synchronizes all firmware to the
versions installed on the primary I/O module.
If the FortiGate-5005FA2 firmware is missing from the primary I/O module, the
FortiGate-5005FA2 modules will keep running their current firmware versions until
you install FortiGate-5005FA2 worker module firmware on the primary I/O module.
You can view the current FortiController-5208 and FortiGate-5005FA2 firmware
versions installed on the primary I/O module from the primary I/O module CLI or
web-based manager.
Viewing the currently installed firmware versions
Upgrading I/O module firmware
Upgrading worker module firmware installed on the primary I/O module
You can view the currently installed I/O module and worker module firmware from
the web-based manager or from the I/O module CLI.
To view the current firmware versions from the web-based manager
1
From the I/O module web-based manager go to System > Status.
2
On the IO Blade status list view the I/O blade firmware version and the worker
firmware version.
To view the current firmware versions from the CLI
1
To view the FortiController-5208 firmware version enter the command:
get system status
2
To view the FortiGate-5005FA2 firmware version enter the following command to
connect to the worker CLI:
execute worker manage
3
Then to view the FortiGate-5005FA2 DIST firmware version enter the following
command:
get system status
Use the following procedures to upgrade the I/O module to a newer firmware
version.
To upgrade the I/O module firmware using the web-based manager
1
Copy the firmware image file to your management computer.
2
Log into the I/O module web-based manager as the super admin, or an
administrator account that has system configuration read and write privileges.
FortiGate-5005-DIST Security System Getting Started