Command
Setting
Code
Hostname
HOSTNAME
Image
SIGNAL.INFO
Information
Modifiers
2403
=?
String
300
?
Mod 1: Zone
Unsigned
0 = ZONE.1
Integer
1 = ZONE.2
2 = ZONE.3
3 = ZONE.4
255 =
CURRENT
[None =
CURRENT]
Mod 2:
Parameter
0 = HACTIVE
1 = VACTIVE
2 = PCLK
3 = HTOTAL
4 = VTOTAL
5 = VREFRESH
6 =
HREFRESH
7 =
INTERLACE
8 =
VFIELDRATE
9 =
VREFRESH.X.
100
10 =
COLORDEPTH
11 = TMDS
[None = ALL]
Planar QE Series RS232 User Manual
Operands
Yes
[Read the current hostname value]
HOSTNAME?
HOSTNAME:"QE Series"
[Set the hostname to "MyDisplay"]
HOSTNAME="MyDisplay"
HOSTNAME:"My Display"
[Invalid host name - can't use spaces]
HOSTNAME="My Display"
HOSTNAME!ERR 5
No
SIGNAL.INFO(CURRENT, HACTIVE)?
SIGNAL.INFO(CURRENT, HACTIVE):1920
Example
Sets the network hostname for
the display. Default string is
"QE Series".
The hostname must be 1-65
characters in length and may
only contain letters and
numbers.
See Main -> Information ->
Image Information
RS232 Codes
Notes