Planar QE Series User Manual page 18

Table of Contents

Advertisement

RS232 Codes
Command
Setting
Code
EDID Timing
EDID.TIMING
EDID Zone
EDID.SELECTEDCO
NNECTOR
Enable
AUDIO.SPEAKERS
Internal
Speakers
Enable
LED.ENABLE
Status LED
Error Log
ERROR.LOG
18
Modifiers
400
=?+-!
Mod 1: Input
0 = OPS
1 = HDMI.1
2 = HDMI.2
3 = HDMI.3
4 = HDMI.4
5 = DP
6 = ALL
Mod 2:
Param
0 = UPDATE
1 = HACTIVE
2 = VACTIVE
3 = VREFRESH
4 =
FULL.SPEC
5 = PCLK
6 = HBLANK
7 = HFP
8 = HSYNC
9 = VBLANK
10 = VFP
11 = VSYNC
12 =
FACTORY
13 = TYPE
401
=?+-
1004
=?+-
1902
=?
2311
?
Log Entry
Number
1-65535
Planar QE Series RS232 User Manual
Operands
Signed Integer
No
[Read the EDID type for HDMI 1]
-3 = 4K60
EDID.TIMING(HDMI.1, TYPE)?
-2 = 4K30
EDID.TIMING(HDMI.1 TYPE):4K60
-1 = 1080P
[Set the HDMI 2 EDID horizontal active to
3840]
EDID.TIMING(HDMI.2, HACTIVE)=3840
EDID.TIMING(HDMI.2 HACTIVE):3840
[Update the HDMI 2 EDID]
EDID.TIMING(HDMI.2, UPDATE)
EDID.TIMING(HDMI.2 UPDATE)@ACK
0 = OPS
No
EDID.SELECTEDCONNECTOR=HDMI.1
1 = HDMI.1
EDID.SELECTEDCONNECTOR:HDMI.1
2 = HDMI.2
3 = HDMI.3
4 = HDMI.4
5 = DP
6 = ALL
0 = OFF
No
AUDIO.SPEAKERS=ON
1 = ON
AUDIO.SPEAKERS:ON
0 = DISABLE
Yes
LED.ENABLE=ENABLE
1 = ENABLE
LED.ENABLE:ENABLE
No
ERROR.LOG(1)?
ERROR.LOG(1):"Wed Sep 16 13:39:33 2015 -
CRIT- Power supply 2 issue"
Example
See Main -> Advanced
Settings -> EDID
UPDATE modifier is the only
one that supports the action
operator
See Main -> Advanced
Settings -> EDID -> Selected
Connector
See Main -> Audio -> Enable
Internal Speakers
See Main -> Advanced
Settings -> System Settings ->
Enable Status LED
Lists any faults that have
occurred in the system. Entry
#1 is the most recent. An
empty string returned means
that there are no more error
log entries after that entry.
Notes

Advertisement

Table of Contents
loading

Table of Contents