U601

Initializing permanent data

Description
Initializes software switches on the FAX control PWB according to the destination and OEM.
Purpose
To initialize the FAX control PWB without changing user registration data.
Method
1. Press the start key.
2. Select [Country Code] and enter a destination code using the numeric keys (refer to the des-
tination code list on following for the destination code).
* : OEM code is no operation necessary.
3. Select [Execute] and press the start key. Data initialization starts. To cancel data initialization,
press the stop key.
4. After data initialization, the entered destination, OEM codes and ROM version are displayed.
A ROM version displays three kinds, application, boot, and IPL.
U603

Setting user data 1

Description
Makes user settings to enable the use of the machine as a fax.
Purpose
To be executed as required.
Method
1. Press the start key.
2. Select [Line Type] and press the start key.
3. Select the setting using the cursor up/down keys.
Display
DTMF
10PPS
20PPS
* : Initial setting: DTMF
4. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Description
DTMF
10 PPS
20 PPS
1-3-49