Item No.
U067

Adjust Table Center

Description
Adjusts the scanner center line of the original scanning.
Purpose
Make the adjustment if there is a regular error between the center lines of the copy image and
original.
Adjustment
1. Press the start key.
2. Press the system menu key.
3. Place an original and press the start key to make a test copy.
4. Press the system menu key.
5. Select the item to be adjusted.
Display
Front
Rotate
6. Change the setting value using the cursor left/right keys or numeric keys.
For copy example 1, decrease the value. For copy example 2, increase the value.
Increasing the value moves the image leftward and decreasing it moves the image rightward.
7. Press the start key. The value is set.
Caution
If the above adjustment does not optimize the center line, proceed with the following mainte-
nance modes.
U034
(P.1-3-17)
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Scanner center line
Scanner center line (rotate
copying)
Center line of the copy image (within ± 2.0 mm)
Original
Figure 1-3-7
U065
U067
(P.1-3-19)
1-3-22
Setting
range
-40 to 40
-40 to 40
Copy
Copy
example 1
example 2
2PV/2PW
Initial
Change in
setting
value per step
0
0.085 mm
0
0.100 mm