(3) Detaching and refitting the main PWB

Procedure
1. Remove the FAX control PWB, if
installed (see page 1-5-36).
2. Remove the right rear cover, right cover
and right lower cover (see page 1-5-6).
3. Remove four screws and then remove
the power source shield.
Screws A and B are unidentical, there-
fore, do not mix up.
4. Open the fan bracket.
5. Slide the fan plate. Release four hooks
and then remove the fan plate.
Screw A
Figure 1-5-43
Hook
Fan plate
Figure 1-5-44
1-5-30
2PV/2PW-1
Screws A
Screw B
Power source shield
Hook
Hook
Hook
Fan bracket