Scan To E-Mail Error Codes - Kyocera ECOSYS M6026cdn Service Manual

Hide thumbs Also See for ECOSYS M6026cdn:
Table of Contents

Advertisement

(3) Scan to E-mail error codes

Code
1101
SMTP/POP3 server does not exist on
the network.
1102
Login to the SMTP/POP3 server has
failed.
1104
The domain the destined address
belongs is prohibited by scanning
restriction.
1105
SMTP protocol is not enabled.
1106
Sender's address is not specified.
2101
Connection to the SMTP/POP3 server
has failed.
2102
Connection to the SMTP/POP3 server
has failed.
(Connection timeout)
The server cannot establish communi-
2103
cation.
2201
Connection to the SMTP/POP3 server
has failed.
2202
Connection to the SMTP/POP3 server
has failed.
(Timeout)
2204
The size of scanning exceeded its limit.
3101
SMTP/POP3 server responded with an
error.
3102
Error: Server Response.
Contents
Check procedures/corrective measures
1. Check the SMTP/POP3 server name.
2. Confirm device's network parameters.
3. Confirm the parameters of the network to which the
device is connected are correct.
1. Confirm user name and password.
2. Check the SMTP/POP3 server.
1. Confirm device's SMTP parameters.
1. Confirm device's SMTP protocols.
1. Confirm device's SMTP protocols.
1. Check the SMTP/POP3 server name.
2. Confirm that the LAN cable is properly connected to
the device.
3. Check the SMTP/POP3 port number.
4. Confirm device's network parameters.
5. Confirm the network parameters the device is con-
nected.
6. Check the SMTP/POP3 server.
1. Check the SMTP/POP3 server name.
2. Check the SMTP/POP3 port number.
3. Confirm device's network parameters.
4. Confirm the network parameters the device is con-
nected.
5. Check the SMTP/POP3 server.
1. Check the SMTP/POP3 server name.
2. Check the SMTP/POP3 port number.
3. Confirm device's network parameters.
4. Confirm the network parameters the device is con-
nected.
5. Check the SMTP/POP3 server.
1. Confirm device's network parameters.
2. Confirm the network parameters the device is con-
nected.
1. Confirm device's network parameters.
2. Confirm the network parameters the device is con-
nected.
1. Confirm device's network parameters.
1. Confirm device's network parameters.
2. Confirm the network parameters the device is con-
nected.
3. Check the SMTP/POP3 server.
1. Check the SMTP/POP3 server.
2. Wait a minute and trye again.
1-4-45