Keypads and Areas

6.4.1

Keypad Area

Master keypad
The AMAX panel supports master keypads. User access to a master keypad differs from user
access to an area keypad. The master keypad switches to the master keypad mode or to the
area that the user declares after entering the user code. The arming/disarming, area alarm, AC
power fault, system fault and system event of each area can be displayed on the master
keypad. The master keypad can also enter the user menu.
It is possible to execute arming/disarming on a master keypad. It is possible to either arm all
areas or to arm only a single area via the direct arm function.
It is not possible to perform a bypass operation on a master keypad. When relevant operations
are made to an area, the master keypad should be switched to the corresponding area.
Area keypad
It is possible to operate each area with a single or multiple independent keypads.
Each area keypad can only operate the corresponding programmed area.
When the area keypad has no corresponding zones, the area keypad cannot be used to
execute zone-related operations such as arming/disarming and bypassing, but can be used to
execute operations unrelated to zones, e.g. event inquiry.
Each area keypad can display the status of the zone belonging to the area. However, for IUI-
AMAX3- LED8 keypad, IUI-AMAXLED 8 keypad and IUI-AMAX-LCD 8 keypad, each area can
display up to 8 zones and cannot display other zones, but can report zone events. For IUI-
AMAX3LED16 keypad, each area can display up to 16 zones and cannot display other zones,
but can report zone events. Keypad IUI -AMAX4-TEXT can display up to 64 zones.
How to program keypads
For keypad no. 1 the default setting is area 01
For keypads no. 2 – 16 the default setting is 99 for not used.
Displaying areas in a LED/LCD keypad
For any area, the logic numbers of the zones are displayed on the LED/LCD keypad and logic
numbers or zone names of the zones are displayed on the keypad instead of actual physical
numbers. For example: The zones 1, 2, and 3 of 1 area or area 1 displayed on the keypad are
actually zones 20, 31, and 37.
6.4.2

Area Timing

The AMAX panel supports separate entry and exit delay times for each area.
Bosch Sicherheitssysteme GmbH
To program a master keypad via installer menu programming, enter area 00 in the section
KEYPAD IN AREA.
To program a master keypad via address programming, enter area 00 into the
corresponding addresses.
To program an area keypad via installer menu programming, enter area 01 – 16 in the
section KEYPAD IN AREA.
To program an area keypad via address programming, enter area 01 – 16 into the
corresponding addresses.
Installation Manual
Settings | en
69
2015.05 | 06 | F.01U.309.277