AMAX panel
1.
2.
3.
23 – External Fault
The external fault zone type performs as described below:
1.
2.
3.
24 – Technical Alarm
The technical alarm zone type performs as described below:
1.
2.
3.
25 – Reset
The reset zone type performs as described below:
1.
2.
3.
Bosch Sicherheitssysteme GmbH
Disarm:
Zone normal - no alarm / no report
Zone triggered - no alarm / no report
AWAY Arm:
Zone normal - no alarm / no report
Zone triggered - no alarm / no report
Zone triggered - during exit time - no alarm / no report
Zone triggered - during entry time - no alarm / no report
STAY Arm: same as AWAY Arm performance.
This zone is mainly for prevention of arming (to ensure exit/entry door is locked
before arming the system and no alarm occurs when entering the premise through
the entry/exit door).
Disarm:
Zone normal - no alarm / no report
Zone triggered - fault / report
AWAY Arm:
Zone normal - no alarm / no report
Zone triggered - alarm / report
Zone triggered - during exit time - fault / report
Zone triggered - during entry time - fault / report
STAY Arm: same as AWAY Arm performance
The restore report will be sent when the zone is restored.
Disarm:
Zone normal - no alarm / no report
Zone triggered - alarm / report
AWAY Arm:
Zone normal - no alarm / no report
Zone triggered - alarm / report
Zone triggered - during exit time - alarm / report
Zone triggered - during entry time - alarm / report
STAY Arm: same as AWAY arm performance.
A technical zone does not send a restore report until the zone is restored.
Disarm:
Zone normal - no alarm / no report
Zone triggered – performs system reset / no report
AWAY Arm:
Zone normal - no alarm / no report
STAY Arm: same as AWAY arm performance
Installation Manual
Settings | en
61