Appendix D. 500 Series RS-232 Fuel/Air Data Input Format

D.1 ELECTRICAL INTERFACE
The input signals shall be compatible with RS-232C. Data shall be input at 9600 baud with a word length
of 8 bits, one stop bit, and no parity. One message will be received per second.
D.2 SHADIN ALTITUDE SENTENCE
The GARMIN 400 Series units shall be capable of receiving the following 17-byte message from Shadin
Altitude Encoders, Altitude Serializers, and Altitude Converters:
Where:
RMS
ASCII characters
<sp>
space (0x20)
<+/->
sign indicator (0x2b["+"] or 0x2d["-"])
12345
altitude in feet
T
ASCII character
<+/->
sign indicator
12
sensor temperature
ul
checksum of bytes 1 through 14 in hex ASCII (i.e., "FA")
<CR>
carriage return (0x0d)
Note: Checksum is calculated by adding each byte in the message (1 through 14).
D.3 ICARUS ALTITUDE SENTENCE
The GARMIN 400 Series units shall be capable of receiving the following 10-byte message from the Icarus
Altitude Serializer:
Where:
ALT
ASCII characters
<sp>
space (0x20)
12345
altitude in feet
<CR>
carriage return (0x0d)
500 SERIES INSTALLATION MANUAL
P/N 190-00181-02
RMS<sp><+/->12345T<+/->12ul<CR>
ALT<sp>12345<CR>
Page D-1