The subsystem is equipped with a serial monitor port allowing you to connect
a PC or terminal.
8. R-Link Port : Remote Link through RJ-45 ethernet for remote manage-
ment
The subsystem is equipped with one 10/100 Ethernet RJ45 LAN port. You use
web-based browser to management RAID subsystem through Ethernet for re-
mote configuration and monitoring.
Link LED: Green LED indicates ethernet is linking.
Access LED: The LED will blink orange when the 100Mbps ethernet is being
accessed.
9. Uninterrupted Power Supply (UPS) Port
The subsystem may come with an optional UPS port allowing you to connect a
UPS device. Connect the cable from the UPS device to the UPS port located
at the rear of the subsystem. This will automatically allow the subsystem to
use the functions and features of the UPS.
10. Power Supply Unit on / off switch
11. System Power On Indicator
Green LED indicates power is on.
12. Controller Fail indicator
If a controller fails, this LED will blink red.
13. Fan Fail indicator
If a fan fails, this LED will turn red.
14. Cooling Fan module 1 ~ 2
Two blower fans are located at the rear of the subsystem. They provide suffi-
cient airflow and heat dispersion inside the chassis. In case a fan fails to
function, the "
" Fan fail LED will turn red and an alarm will sound.
2-7