Hardware Monitor - Fantom Drives MGD-16FC16S Installation Reference Manual

Raid fibre to s-ata/sas
Hide thumbs Also See for MGD-16FC16S:
Table of Contents

Advertisement

3.10.3 Hardware Monitor

To view the RAID subsystem controller's hardware monitor information, move the
mouse cursor to the main menu and click the Hardware Monitor link. The Hard-
ware Information screen appears.
The Hardware Monitor Information provides the temperature, fan speed (chassis
fan) and voltage of the internal RAID subsystem. All items are also unchangeable.
The warning messages will indicate through the LCD, LED and alarm buzzer.
Item
Controller Board Temperature
HDD Temperature
Controller Fan Speed
Power Supply +12V
Power Supply +5V
Power Supply +3.3V
DDR Supply Voltage +2.5V
CPU Core Voltage +1.3V
DDR Termination Power +1.25V
Warning Condition
> 70 Celsius
> 65 Celsius
< 1500 RPM
< 10.5V or > 13.5V
< 4.7V or > 5.4V
< 3.0V or > 3.6V
< 2.25V or > 2.75V
< 1.17V or > 1.43V
< 1.125V or > 1.375V
Configuring
3-65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mgd-16fc16a

Table of Contents