Comfort Settings
This tool is available in all communicating systems. This screen is used to control comfort settings.
These settings effect how the Touch Screen Communicating Control will satisfy calls for condition-
ing.
Humidity Settings: The humidity settings screen is used to change the humidify/dehumidify set-
tings to fit the equipment installed.
Humidification settings (Available only with humidifier installed)
Humidification with a heat demand: If this option is selected the control will only activate the
humidifier if there is a demand for both heating and humidity.
Humidification with or without a heat demand: If this option is selected the control will activate
the humidifier any time there is a humidity demand.
This is for use with hot water or steam humidifiers.
No Humidification: The control will never activate the humidifier.
Dehumidification settings
De-Humidification with equipment: If this option is selected the control will only dehumidify by
running a reduced airflow on the indoor equipment
equipment).
De-Humidification by overcooling: If this option is selected the control will continue to run cooling
up to 3 degrees below set point to meet humidity setting of the home (selectable from 1-3 degrees).
De-Humidification with external equipment: If this option is selected, there should be an external
(whole home) de-humidifier.
This option may require a communication accessory control.
No De-Humidification: If this option is selected the control will not send a command to de-humid-
ify.
Smart Recovery: (ON, OFF) Smart recovery is used in programmable or advanced programmable
mode. The controller initiates equipment operation, if required, before the start time of the program
schedule day part. This is done to reach the program schedule event's desired temperature setpoint
at the time the event occurs, rather than after.
Temperature Control Settings: Temperature Control Settings screen is used to customize how the
Touch Screen Communicating Control will satisfy temperature set point. As well as, how the control
will stage the installed equipment. The Touch Screen Communicating Control can be set up to sat-
isfy demand differently depending on whether there is a heat demand or a cool demand.
Below is a table of explaining each of the available settings.
Johnson Controls Unitary Products
NOTICE
(Available only with communicating indoor
1078329-UIM-A-0114